Swiss Calibration Laboratory for Force and Torque

Accredited calibration laboratory (SCS 0083)

Accredited calibration
for force and torque measuring devices
ISO/IEC 17025 (SCS 0083) – traceable and documented

 

   

 

https://www.disa.ch/wp-content/uploads/DSC_00459.jpg

Calibrate force and torque measuring devices: accredited to ISO/IEC 17025

Maximum process reliability starts with reliable measuring equipment. In our ISO/IEC 17025-accredited calibration laboratory (SCS 0083) in Sarnen, we calibrate force and torque measuring devices and sensors, in accordance with standards, traceable and documented. Depending on your requirements, you will receive an SCS calibration certificate or a factory test report for your test equipment monitoring.

Request calibration or call us directly: +41 41 666 70 50

Why calibrate at DISA?

  • Accredited quality: Laboratory according to ISO/IEC 17025 (SCS 0083), metrologically traceable.
  • Suitable for your measuring range: Force (SCS up to 50 kN, factory up to 200 kN) and torque (SCS/factory up to 1000 Nm).
  • Fast turnaround time: Normal 5 to 8 working days from the Sarnen laboratory; express up to 3 working days.
  • Documentation as required: SCS certificate for audits and regulations or factory report for internal records.
  • Expertise in force measurement: From calibration to engineering and strain gauge application, everything from a single source.
  • Official Mark-10 Service Center: Responsible for Europe since 2011. We calibrate and repair Mark-10 force and torque measuring devices with the manufacturer’s know-how.

Our calibration scope

Force
Calibration of force measuring devices and sensors (tension/compression), including test stands and display units. Measuring points according to standard or specification, including documentation and traceability.
Measuring ranges: SCS up to 50 kN, factory calibration up to 200 kN.

Torque
Calibration of torque measuring devices and sensors for test stands and measuring setups, with traceable documentation for QA and audits.
Measuring ranges: SCS/factory up to 1000 Nm.

Measuring ranges and measurement uncertainty (SCS 0083)

Quantity and measuring range Measuring conditions Measurement uncertainty (CMC)
Torque
0.01 Nm to 6 Nm
Via torque generating disc and load pieces ± 0.5 %, but not less than 0.002 Nm
Torque
0.5 Nm to 1000 Nm
Via horizontal double lever arm and load pieces ± 0.4 %, but not less than 0.002 Nm
Force (tension and compression)
0.01 N to 1000 N
With load pieces ± 0.1 %
Force (tension and compression)
1.0 kN to 10 kN
With force transducer class 0.5 ± 0.25 %
Force (tension and compression)
5.0 kN to 50 kN
With force transducer class 0.5 ± 0.2 %

The stated expanded measurement uncertainty is the standard uncertainty of the measurement multiplied by the coverage factor k = 2, which corresponds to a confidence level of approximately 95 % for a normal distribution. Source: SCS directory, accreditation number SCS 0083. Factory calibrations are possible for force up to 200 kN.

Certificates and evidence

  • SCS calibration certificate: Accredited, traceable calibration according to ISO/IEC 17025, ideal for certified QM systems (e.g. ISO 9001).
  • Factory test report: Economical option for internal test equipment monitoring when no accreditation is required.

What determines the price of a calibration

  • Device type: force or torque, measuring device or sensor
  • Measuring range of the device
  • Type of certificate: SCS calibration certificate or factory test report
  • Number of devices

You will find the current prices in the price list below under “Documents”. For a quotation, the device type, measuring range and desired certificate are enough.

Process and lead time

  1. Request and device specification (device type, measuring range, desired certificate)
  2. Goods receipt at the Sarnen laboratory and incoming inspection
  3. Calibration according to standard or specification, incl. documentation of the measuring points
  4. Review and certificate issue (SCS or factory)
  5. Return shipment: normal 5 to 8 working days, express up to 3 working days

Suitable measuring equipment

Force measuring devices, force sensors, test stands, display and evaluation devices; torque measuring devices, torque sensors, test stands capable of torque measurement. We agree on variants (e.g. tension/compression, mounting position, ascending load) with you project by project.

Typical areas of use

Quality assurance, goods receipt, test laboratory, production, maintenance, development and engineering: wherever reproducible measurements are decisive.

What you receive from us

  • Certificate/report with measuring points and traceability
  • Transparent scope of services depending on measuring range and device
  • Advice on test setups, adapters and software integration

Frequently asked questions about calibration

What is the difference between an SCS calibration certificate and a factory test report?
The SCS calibration certificate documents an accredited, traceable calibration according to ISO/IEC 17025. It is suitable for audits and certified QM systems. The factory test report is the economical option for internal test equipment monitoring when no accreditation is required. SCS stands for the Swiss Calibration Service: the calibration laboratories are accredited by the SAS, and traceability leads back to the national standards of METAS. It is used for measurements that safeguard quality in industry, research and trades.

How long does a calibration take?
Normal 5 to 8 working days from the Sarnen laboratory. Express up to 3 working days.

Which devices can be calibrated?
Force measuring devices, force sensors, test stands and display devices as well as torque measuring devices and torque sensors. We agree on variants with you project by project.

How often should measuring equipment be calibrated?
An interval of 12 months is a good starting point for many industrial measuring instruments. However, the interval should be set on a risk basis and reviewed regularly against the actual calibration results.

  • Load: mechanical stress or improper handling can lead to deviations.
  • Environmental conditions: temperature, humidity, dust and vibrations can affect measurement accuracy.
  • Measurement accuracy: the higher the required accuracy, the more important regular checks are.
  • Frequency of use: frequently used equipment can wear out faster.

What happens if a device is outside tolerance?
If a device is outside tolerance (manufacturer tolerance or tolerance specified by the customer), the procedure depends on the work carried out:

Action Before (as found) After (as left)
Regular calibration Calibration –
Repair Document condition, calibrate if possible Calibration mandatory
Adjustment Calibration mandatory Calibration mandatory
Repair and adjustment combined Calibration if possible Calibration after all work is completed

Documents

Accreditation and directories

Calibration prices

Request a calibration quote

Tell us briefly which devices need to be calibrated. We will get back to you personally.

    Type of calibration

    Contact

    DISA AG Sarnen
    Kägiswilerstrasse 33
    CH – 6060 Sarnen

    Phone: +41 41 666 70 50
    Email: info@disa.ch

    To Engineering & Test Setup
    To Force Measurement

    Zdenko Duchon

    Zdenko Duchon

    Head of the Calibration Laboratory

    zdenko.duchon@disa.ch

    +41 41 666 70 42

    Dominik Ming

    Dominik Ming

    Head of Engineering and Assistant Head of the Calibration Laboratory

    dominik.ming@disa.ch

    +41 41 666 70 41

    Shopping Cart
    Scroll to Top

    Unsere Kompetenzen

    Produkte und Dienstleistungen aus einer Hand

    Von der Messung über die Schraubtechnik bis zur Kalibrierung im eigenen Labor. Wir begleiten Sie von der Auswahl bis zum Service.

    Alle Produkte ansehen

    Unsere Marken

    Starke Marken, persönliche Beratung

    Wir arbeiten mit ausgewählten Herstellern zusammen und beraten Sie persönlich bei der Wahl der passenden Lösung.

    Alle Partner ansehen
    • Mark-10
    • FIAM
    • n-gineric
    • HS-Technik
    • 3R Industries
    • HIOS
    • Ohtake
    • NCTE
    • ETH Messtechnik
    • Barrus
    • Starrett
    • GRIP Engineering
    • Delvo
    • Arno Arnold
    • Elektra Tailfingen